If you typed Gotuzzo Asociados into a search box, you are probably building a CRO or site shortlist for Peru. This article uses only what is public about Gotuzzo Asociados (LinkedIn company page) and compares it with bioaccess®, the First-in-Human CRO for medical devices in Latin America since 2010. It is a practitioner comparison, not a teardown.
What Gotuzzo Asociados publishes
Gotuzzo Asociados S.A.C. is a Lima-based (Miraflores) clinical research services firm. Its public company profile describes services such as acting as legal representative before Peru’s INS, regulatory affairs, monitoring, investigational product import and translation. It appears as ROIC-96 in the INS register of research organizations (OIC).
Gotuzzo Asociados vs bioaccess®
Dimension
Gotuzzo Asociados
bioaccess®
Core focus
Peru legal representation, regulatory, monitoring
First-in-human and early feasibility studies for medical devices
Geography
Peru (Lima)
Latin America, since 2010
Device FIH track record
No named device first-in-human study found on the public pages reviewed
Published case studies on bioaccessla.com
After the trial
See provider site
Live multi-country sanitary registration and in-country holder service
Where each one fits
If you need an INS legal representative and local regulatory and monitoring support for a drug study in Peru, Gotuzzo Asociados’ published services match.
If the job is a first-in-human or early feasibility study for a medical device, bioaccess® is a specialist built for exactly that, running device studies in Latin America since 2010. When the study ends, the same company can register and hold the device across the region through its market access service. Ask any CRO or site on your list, including Gotuzzo Asociados, for a named or de-identified device first-in-human study: device class, implant or not, number of patients, ISO 14155 monitoring plan and how the data was used in an FDA file.
Facts from the Gotuzzo Asociados public pages linked above, Peru’s INS public registers and ClinicalTrials.gov, reviewed for bioaccess® competitive research (Oct 2026). Claims are theirs. No invented sponsors, prices or contacts.
Almost every first-in-human device sponsor I work with asks some version of the same question once the protocol starts taking shape: do we need a data monitoring committee, a clinical events committee, a medical monitor, or all three? Founders hear the acronyms from investors, from their FDA consultant and from the ethics committee, and they assume each one is a box to tick. In a 10- to 20-patient early study, buying all three can cost more than it protects. Leaving out the wrong one can stall the study the first time something goes wrong.
I am Julio Martinez-Clark, CEO of bioaccess®. This page explains what each of the three safety-oversight roles actually does in a first-in-human (FIH) or early feasibility device study, what FDA and Brazil’s ANVISA say about them, and how I size them for a small study in Latin America. It goes with our guide to stopping rules and staggered enrollment in an FIH device study, the ISO 14155 inspectable file and our early feasibility studies page. This is operator guidance, not legal or regulatory advice; check the current text of each regulation before you finalize your plan.
One-sentence answer
A medical monitor is the sponsor’s physician who reviews safety events as they happen, a clinical events committee (CEC) independently classifies events and endpoints against definitions written in advance, and a data monitoring committee (DMC, also called a DSMB) independently reviews the accumulating data and recommends whether the study should continue; a small FIH device study almost always needs the first, usually benefits from a lean version of the second, and needs the third when the risk analysis, the population or the regulator calls for it, which in Brazil includes every pivotal study of a Class III or IV device.
What each role does
Medical monitor
The medical monitor is a physician working for, or contracted by, the sponsor. They review serious adverse events as they come in, answer investigators’ protocol and eligibility questions, judge whether an event is a potential unanticipated adverse device effect, and make sure the reporting clocks start. They are not independent of the sponsor, and nobody expects them to be. Their value is speed: in an FIH study the first serious event usually needs a medical decision the same day.
Clinical events committee
A CEC is a small panel of independent physicians, often two or three specialists in the therapeutic area, who adjudicate events against definitions fixed in the protocol or a CEC charter before the first patient is enrolled. They decide whether an event meets the definition of a serious adverse event or a primary endpoint event, and whether it is related to the device, the procedure, or neither. They do not decide whether the study continues. Their output is consistency: the same event at two sites gets the same classification, and an investigator who is enthusiastic about the device is not the only person deciding whether it caused a complication.
Data monitoring committee
A DMC is a group of independent experts, typically clinicians plus a statistician and sometimes an ethicist, that reviews accumulating safety (and sometimes effectiveness) data at planned points and recommends to the sponsor whether to continue, modify or stop the study. FDA’s February 2024 draft guidance, Use of Data Monitoring Committees in Clinical Trials, which when finalized replaces the March 2006 guidance on establishing and operating DMCs, describes exactly this function. The DMC recommends; the sponsor decides and owns the consequences.
What FDA says
Under FDA regulations, sponsors are not required to use a DMC except in the narrow emergency-research setting of 21 CFR 50.24(a)(7)(iv). Device sponsors are, however, required to monitor their investigations under 21 CFR Part 812 (812.40 and 812.46), and unanticipated adverse device effects must be evaluated and reported within 10 working days under 21 CFR 812.150.
The tone has shifted. The 2006 guidance said DMCs were not needed for most studies, particularly early ones. The 2024 draft drops that language and notes that DMCs are now used in early-phase trials in serious diseases or conditions and where causality of adverse events is hard to judge without seeing the full data. FDA’s early feasibility study guidance (section 7.4.2) names a data monitoring committee of clinicians, scientific experts and people with ethics expertise as one possible risk-mitigation element for an early device study. Neither document makes a DMC mandatory for an FIH device study. Both make it something your reviewer may ask about.
What Brazil adds
ANVISA’s RDC 837 of 13 December 2023, which governs device clinical investigations in Brazil, is more specific. Under Art. 57 the sponsor must consider a DMC before the study starts, based on its risk analysis of the device and of study participation. Pivotal studies of Class III and IV devices must have one, and its recommendations go to ANVISA as an amendment (aditamento) within 30 calendar days. The DMC’s functions belong in the clinical investigation plan, and if you decide not to set one up, the plan has to justify that decision. Art. 54 adds that the sponsor, or an independent DMC, evaluates adverse events in aggregate, and that evaluation feeds the annual reports.
So for an FIH study in Brazil, “we didn’t think about it” is not an available answer. You either have a DMC or a written justification for not having one.
ISO 14155:2020, the standard most Latin American ethics committees and regulators expect device sponsors to follow, treats a DMC as optional and expects the clinical investigation plan to say whether one is used and how it works. Ethics committees in the region read that section closely in first-in-human protocols.
How I size oversight for a small FIH study
Always name a medical monitor with a phone number the sites can reach on the day of the procedure. For a study run in Latin America, that person needs to be reachable in the sites’ time zone and comfortable reading source documents in Spanish or Portuguese.
Use a lean CEC when the endpoints involve judgment. If your primary safety endpoint is “major adverse events at 30 days” and relatedness to device versus procedure matters to your FDA story, two or three independent adjudicators with a short charter and pre-written definitions are usually worth it. If the endpoint is a simple, objective measurement, a CEC may add little.
Decide on the DMC against the risk file, not habit. Implantables, life-sustaining devices, fragile populations, follow-up longer than a few months, or a Brazilian pivotal Class III/IV study point toward a DMC. A short, single-country study of a low-risk procedure with staged enrollment may be well served by an independent safety reviewer instead, with the reasoning written into the plan.
Combine roles carefully in very small studies. In a 10-patient study, one small independent committee can sometimes adjudicate events and also make continuation recommendations, as long as its charter says so, its members have no financial stake in the device, and investigators do not vote on their own restart.
Write the charter before first patient in. Membership, conflicts of interest, meeting triggers (for example, after each of the first few subjects and after any serious event), what data the committee sees, how recommendations reach the sponsor, and who tells the ethics committee and regulator.
Common mistakes I see
A DMC charter that exists on paper but whose first meeting is scheduled after the last subject is treated.
The sponsor’s chief medical officer sitting on the “independent” committee.
Event definitions that differ between the protocol, the CEC charter and the case report forms, so the adjudicators are classifying against a moving target.
No plan for who translates source documents for an adjudicator who does not read Spanish or Portuguese.
Treating the DMC’s recommendation as the regulatory report. In Brazil the sponsor still has to file it with ANVISA; in a US-bound program the sponsor still owns 812.150 reporting.
How bioaccess® runs this
In the first-in-human and early feasibility studies we run in Latin America, we set up the medical monitoring, the adjudication workflow and, where needed, the DMC charter as part of study start-up, and we map each committee’s output to the reporting clocks of every regulator involved: ANVISA, INVIMA, COFEPRIS, Panama’s MINSA, and FDA when the data will support a US submission. The goal is an oversight structure sized to a 10- to 30-patient study that still reads as rigorous to an FDA reviewer looking back at it.
FAQ
Is a DMC the same as a DSMB?
Yes. FDA’s guidance treats data monitoring committee, data and safety monitoring board (DSMB), data and safety monitoring committee and independent data monitoring committee as names for the same function.
Does FDA require a DMC for an early feasibility device study?
No. FDA does not require one outside the emergency-research exception in 21 CFR 50.24. Its early feasibility guidance lists a DMC as one possible risk-mitigation element, and reviewers may ask how you will oversee safety if you do not have one.
Does Brazil require a DMC?
For pivotal studies of Class III and IV devices, yes (RDC 837/2023, Art. 57). For other studies the sponsor must consider one based on its risk analysis and justify the decision in the clinical investigation plan if it does not set one up.
Can the CEC and DMC be the same people?
In a very small study, sometimes, if the charter defines both functions and the members are independent of the sponsor and the investigators. In larger studies they are usually kept separate.
Who pays the committee members?
The sponsor, under written agreements that disclose fees and conflicts of interest. Payment does not compromise independence as long as it is fixed and not tied to the study’s outcome.
Sources: FDA, Use of Data Monitoring Committees in Clinical Trials, draft guidance (February 2024) and Federal Register notice 2024-02849; FDA, Establishment and Operation of Clinical Trial Data Monitoring Committees (March 2006); FDA, Investigational Device Exemptions (IDEs) for Early Feasibility Medical Device Clinical Studies, section 7.4.2; 21 CFR 50.24, 812.40, 812.46 and 812.150; ANVISA RDC 837/2023, Arts. 54 and 57; ISO 14155:2020.
General information, not legal or regulatory advice. Review clocks are cited to the regulation or the regulator’s own guidance. Durations marked “bioaccess® experience” are planning estimates from our recent study timelines, not legal deadlines or guarantees. bioaccess® runs studies in all three regions, so this guide sets out the trade-offs rather than a single answer. Sources last checked: 29 October 2026.
There is no single best region. The right choice depends on what the first study has to do for your program.
The United States fits when you want FDA to shape the study with you from the start, when US investigators matter for the next study, or when investors want US data. FDA’s review clock is 30 days for both an IND (drugs) and an IDE (devices). The time usually goes into the pre-submission work, institutional review and contracts around it.
Canada fits drug studies that want a 30-day default review (the trial is authorized if Health Canada does not object within 30 days), and device studies that can work with a 30-day review target, where the authorization for Class III and IV devices can be issued before ethics approval. Canada is also on FDA’s lists of countries with simplified export of investigational products.
Latin America fits when activation speed, patient access and cost are the binding constraints, and when the study is designed from day one so FDA can accept the data. The regulator clock and review order vary by country: from parallel ethics and regulator review timed to each committee’s meeting schedule (Panama), to several months for drug trials where the regulator clock is long (Brazil: ANVISA 90 business days) or starts after ethics (Colombia: INVIMA 60 business days).
Many programs use more than one region in sequence. The data rules below decide whether that works.
Review clocks at a glance
Published review milestones with different start and end points, approximate calendar days (business days × 7/5). Not approval or time to first patient.
The chart shows different published review milestones, not comparable approval or activation durations: the IND clock starts at FDA receipt, the CTA at receipt of a complete application, the ITA at the start of screening, and Colombia’s is a first response after ethics. Panama includes ethics review (up to 20 business days, 10 expedited, or 30 in total for full-committee review). It is not the time to first patient. Business days are converted to calendar days at about 7 calendar days per 5 business days, before holidays.
Side by side: US, Canada and Latin America
Question
United States
Canada
Latin America
Drug application
IND to FDA
Clinical Trial Application (CTA) to Health Canada
National regulator application; varies by country
Device application
IDE to FDA for significant-risk devices; non-significant-risk studies follow abbreviated IDE requirements with IRB approval
Investigational Testing Authorization (ITA) for unlicensed Class II, III and IV devices; none for Class I
Varies by country; confirm with us
Regulator clock
IND takes effect after 30 days unless FDA places a clinical hold; an IDE study may begin after 30 days unless FDA objects (21 CFR 312.40; 21 CFR 812.30)
About 4 weeks (Panama) to about 4 months (Brazil, drug dossiers); see the table below
What happens if the regulator says nothing
IND takes effect after 30 days unless FDA places a clinical hold
CTA: authorized if no objection within 30 days. ITA: no automatic authorization
Depends on the country
Ethics review
IRB at each site, or a central IRB
Research Ethics Board (REB) per site
Ethics committee per site or national committee; order varies
Ethics and regulator in parallel?
Yes; IRB and FDA run separately
Yes. For Class III and IV devices, the ITA letter can issue before REB approval
Parallel in some countries (Panama; El Salvador (bioaccess® experience); Brazil submissions); sequential in others
Local presence needed
FDA states that the sponsor of an IDE must be located in the US
CTA attestation by a senior medical or scientific officer residing in Canada
Varies by country; an importer of record is needed for the product. Confirm with us
Regulator fee
Confirm with us
CTAs and ITAs carry no Health Canada fee
Varies; confirm with us
Labels
US investigational labeling
Drugs and devices: investigational statements in English and French
Local-language labels in several countries (for example Spanish in Panama and Chile)
Export from the US
Not needed
Simplified: Canada is on FDA’s tier-one list for devices and on the listed countries in 21 CFR 312.110(b) for drugs
Devices need FDA export approval under 801(e)(2); drugs ship under an IND in effect or, subject to its conditions, an export certification (21 CFR 312.110)
FDA use of the data
Collected under the IND or IDE
Foreign data: 312.120 (drug studies not conducted under an IND) and 812.28 (devices)
Same as Canada
United States: IND, IDE and early feasibility studies
Drugs. An IND goes into effect 30 days after FDA receives it, unless FDA places the study on clinical hold, or earlier if FDA says so (21 CFR 312.40). FDA offers pre-IND meetings before the filing.
Devices. For a significant-risk device, the study can begin 30 days after FDA receives the IDE unless FDA objects, or when FDA approves it by order. FDA can approve, approve with modifications, or disapprove (21 CFR 812.30). Non-significant-risk device studies follow abbreviated requirements with IRB approval (21 CFR 812.2(b)). See IDE vs IND, what to send in a Q-Submission and IDE steps after you submit.
Early feasibility studies (EFS). An EFS is a small, early device study, typically before the design is final, used to check the concept and guide changes. FDA’s EFS Program offers interactive review, help from an EFS representative, potentially less non-clinical data when clinical risk mitigations are in place, and faster ways to change the device or protocol. FDA recommends a Pre-Submission before the IDE (FDA EFS Program; 2013 guidance on IDEs for early feasibility studies, including certain first-in-human studies).
Where the US time goes. The 30-day clock is often not the longest step. Pre-submission meetings, approval-with-modifications rounds, institutional review, hospital contracts and clinical-trial insurance add the time. Across regions, an industry benchmark found an average of 31.4 weeks from site identification to completed start-up, with repeat sites 9.9 weeks faster (Tufts CSDD, 2018).
Canada: CTA and ITA
Drugs (CTA). A sponsor needs a Clinical Trial Application to sell or import a drug for a phase I to III trial. Health Canada has 30 days from receipt of a complete application to object; without an objection the trial is authorized, and Health Canada typically issues a No Objection Letter. Answers to questions during review are due within 2 calendar days (CTA guidance).
The 7-day review is narrower than many sources suggest. Health Canada’s 7-day administrative target applies only to comparative bioavailability studies of pharmaceuticals: single dose, healthy adults, a reference product marketed in Canada, the US or a few other listed countries, and a study dose no higher than the reference product’s labeled maximum. It does not apply to biologics, cell or gene therapies, or to other studies such as first-in-human studies of a new drug, which follow the 30-day default (CTA guidance, 2.3.3; performance standards).
Devices (ITA). Unlicensed Class II, III and IV devices need an Investigational Testing Authorization; Class I devices do not. The review target is 30 calendar days from the start of screening. It is a target, not a default: there is no automatic authorization. Screening deficiencies must be fixed within 15 calendar days. If Health Canada asks for more information after review, the applicant has 60 days to answer and a new 30-day review starts. The manufacturer or importer applies. For Class III and IV devices, the Letter of Authorization can be issued before REB approval, as long as at least one qualified investigator is named; REB approval must reach Health Canada before the study starts. ITA applications carry no fee, and pre-ITA meetings are available (ITA guidance).
Practical points. Drug labels must carry the required information in English and French, and device labels need the investigational statements in both languages. The CTA must be attested by a senior medical or scientific officer residing in Canada. Our Canada page compares Canada and Latin America for first-in-human device trials.
Latin America: regulators and review order
Latin America is not one pathway. The order of ethics and regulator review is the biggest difference between countries. These are the published clocks; our site activation guide has the full country notes and sources.
Country
Regulator
Order
Published clock
Panama
MINSA; DNFD for medicines and health products
Ethics and ministry in parallel
Ethics up to 20 business days (10 expedited; 30 in total if the full committee reviews); DNFD 15 business days (Executive Decree 21 of 2026)
El Salvador
SRS with the national ethics committee (CNEIS)
One submission, parallel review (bioaccess® experience)
No published clock; about 47 to 85 days to approval (bioaccess® experience)
Costa Rica
CONIS
Accredited ethics committee first, then CONIS registration
CONIS acknowledges a complete registration within 5 business days; technical report within 10 business days
Brazil
ANVISA
Can be submitted in parallel; drug trials start after both approve
ANVISA 90 business days for drug dossiers (RDC 945/2024); ethics 10 working days to check plus 30 days (Law 14,874)
Colombia
INVIMA
Ethics first, then INVIMA
First INVIMA response within 60 business days for drug protocols (INVIMA guide GU039)
Mexico
COFEPRIS
Institutional committees first, then COFEPRIS
30 business days under the health research regulation (COFEPRIS guidance states 30 calendar days; confirm with us)
Argentina
ANMAT
Confirm with us
Drug studies: 20 + 10 or 35 + 10 business days of technical and administrative review (Disposition 7516/2025)
Chile
ISP
Ethics report and ISP authorization for drug trials
45-day term, average evaluation 28 business days, reported by InvestChile
Ecuador
ARCSA
Ethics committee (CEISH) first, then ARCSA
Document check in 7 days, then up to 60 days of technical review (extendable by 30)
Peru
INS
Ethics first, then INS
Up to 30 working days
bioaccess® runs first-in-human studies in Colombia now.
In our recent plans, the quickest-review countries reached first patient about 8 to 9 months from a protocol synopsis, or about 4.5 to 6 months from a final protocol(bioaccess® experience). Ethics committee calendars and turnaround are practice, not law, and they vary by committee.
Will FDA accept data from outside the US?
Yes, when the study is designed and run for it. It is never automatic.
Drugs. FDA accepts a well-designed, well-conducted foreign study not run under an IND if it followed good clinical practice, including independent ethics committee review and informed consent, and FDA can validate the data through an onsite inspection if needed. The sponsor describes the steps taken to meet GCP (21 CFR 312.120). Approval based only on foreign data is governed separately (21 CFR 314.106).
Devices. For investigations that began on or after 21 February 2019, FDA accepts data from outside the US to support an IDE, 510(k), De Novo or PMA if the investigation is well designed and conducted, a GCP statement and the supporting information are provided, and FDA can validate the data (21 CFR 812.28). FDA notes that an IDE is not needed for a study conducted entirely at foreign sites, but FDA decides whether to accept the data (FDA).
Canada and Latin America are treated the same way. For FDA, both are foreign data. What matters is how the study was run, not the country.
Design rules that protect acceptance: follow ISO 14155 for devices and ICH GCP for drugs, use an independent ethics committee, keep source documents and device accountability inspection-ready, and show FDA your plan in a pre-submission meeting before the study starts. More detail: Panama and El Salvador data for an FDA IDE, 510(k) or De Novo.
Decision guide: which region fits your program
If your priority is…
Consider
Why
Iterating the device with FDA from the first case
United States (EFS)
FDA’s EFS Program is built for interactive review and fast design changes
US investigators who will run the pivotal study
United States
Early experience stays with US sites
A 30-day default drug review
Canada
30-day CTA default, separate REB review
A device authorization that does not wait for ethics approval
Canada
Class III and IV ITA letters can issue before REB approval
A simplified export from the US
Canada
Tier-one country for FDA device export; listed country in 21 CFR 312.110(b) for drugs
Short review where ethics and regulator run in parallel
Latin America (for example Panama; El Salvador (bioaccess® experience))
Parallel ethics and regulator review
Patient access and enrollment throughput
Latin America
Depends on the indication and the site; confirm with feasibility
Lower study cost
Compare study-specific budgets in each region
In our studies Latin American site costs have been lower than US costs (bioaccess® experience); see our line-by-line budget guide
Data that must support an FDA submission
Any region
In the US, run under the IND or IDE; outside the US, design for 312.120 or 812.28 from day one
Hybrid plans
Common sequences in our practice:
Latin America first-in-human, then a US EFS or feasibility study. First human data before the US study; FDA sees the plan in a pre-submission.
A US EFS with a parallel cohort in Canada or Latin America. US FDA interaction plus enrollment from other sites under one protocol.
Canada for a drug phase 1, then Latin American and US sites for phase 2.
For cardiovascular devices, our sister organization Amavita Research runs a site in Miami, so one team can coordinate a US arm and a Latin American arm. See also US vs Latin America for first-in-human.
Questions to answer before you choose
Which FDA submission will this study support, and has FDA seen the plan?
Is the product used in the study identical to the one you will file, or do you need a documented comparison?
Who is the sponsor of record in each country, and who is the importer of record?
Which ethics committees review, how often do they meet, and in what language do they want the file?
Can the sites’ source documents and accountability logs pass an FDA inspection?
Do the sites see enough of your patients, and can they keep them through follow-up?
What is the export route from the US for your product?
Glossary
IND: Investigational New Drug application to FDA.
IDE: Investigational Device Exemption from FDA, for significant-risk device studies.
EFS: early feasibility study; a small, early device study, often first-in-human.
Q-Submission (Pre-Sub): a request for FDA feedback before a submission.
CTA: Clinical Trial Application to Health Canada (drugs).
NOL: No Objection Letter from Health Canada.
ITA: Investigational Testing Authorization from Health Canada (devices).
REB / IRB / ethics committee: the independent committee that reviews the study for participant protection.
GCP: good clinical practice (ICH E6 for drugs, ISO 14155 for devices).
Tier-one country: FDA’s short list of countries with simplified export of investigational devices; a similar country list applies to drugs in 21 CFR 312.110(b). No Latin American country is on either list.
Frequently asked questions
Is Canada’s CTA review really 7 days for phase 1?
Only for comparative bioavailability studies of pharmaceuticals in healthy adults that meet Health Canada’s criteria. A first-in-human study of a new drug follows the 30-day default review.
How long does FDA take to review an IND or IDE?
30 days from receipt. An IND takes effect after 30 days unless FDA places a clinical hold; an IDE study may begin after 30 days unless FDA objects, or earlier if FDA approves it by order.
Does Health Canada’s ITA authorize a device automatically after 30 days?
No. The 30 days is a review target, not a default. Health Canada issues a Letter of Authorization when the application meets the requirements.
Do I need an IDE to run a device study only in Latin America or Canada?
FDA says an IDE is not needed for a study conducted entirely at foreign sites. You still need the local approvals, and FDA evaluates the data under 812.28 when you submit it.
Will FDA accept first-in-human data from Latin America or Canada?
It can, when the study meets 21 CFR 312.120 (foreign drug studies not conducted under an IND) or 812.28 (devices): good clinical practice, independent ethics review, consent and data FDA can validate. Acceptance is decided per submission.
Which region is fastest to first patient?
It depends on the country and the study. FDA’s IND and IDE clocks are 30 days; Health Canada’s CTA has a 30-day default and the ITA a 30-calendar-day target from the start of screening, with no automatic authorization. In Latin America, published clocks range from about 4 weeks (Panama, parallel review) to several months where clocks are long or sequential. In our recent plans, the quickest-review Latin American countries reached first patient about 4.5 to 6 months from a final protocol (bioaccess® experience).
Which region is cheapest?
It depends on the study, the procedure and the sites, so compare study-specific budgets. In our studies, Latin American site costs have been lower than US costs (bioaccess® experience). See our sample budget.
Can I combine regions?
Yes. Some programs run a first-in-human cohort in one region and the next study in another, or a parallel cohort under one protocol. One regulatory strategy should cover all the regions.
What does Canada require that the US does not?
English and French label statements, and a CTA attestation by a senior medical or scientific officer residing in Canada.
Are these clocks calendar days or business days?
FDA and Health Canada clocks are calendar days. Most Latin American clocks are business days, so 30 business days is about 6 weeks on the calendar before holidays. The country table says which unit each clock uses.
Talk through your plan
Send us your synopsis and the FDA submission you are aiming for. We will tell you which regions and countries fit, and which don’t. Contact bioaccess®.
When a US or European manufacturer asks me who should hold its ANVISA registration in Brazil, the conversation usually centers on dossiers and timelines. The question I push onto the table early is a different one: when something goes wrong with a device that is already on the Brazilian market, who has to act, and how fast? In Brazil the answer is written into one resolution, and it lands squarely on the registration holder.
I am Julio Martinez-Clark, CEO of bioaccess®. This page explains what ANVISA’s RDC 551/2021 requires of a registration holder when a marketed medical device needs a field action (a recall, a correction, or a safety alert), and what that means for how you set up your holder in Brazil. It sits next to our Brazil ANVISA market-access page, the guide to the LATAM registration holder and importer of record and the guide to transferring a registration to a new holder. This is operator guidance, not legal advice. Check the current text of the resolution and ANVISA’s forms before you act on a live event.
One-sentence answer
Under ANVISA RDC 551/2021, the Brazilian registration holder must start a field action as soon as there is sufficient evidence that a marketed device does not meet its essential safety and performance requirements, notify ANVISA within 3, 10 or 30 calendar days of deciding to act depending on the risk, get ANVISA’s prior approval within 5 calendar days for any alert that runs in mass media, issue a clear alert message, file monitoring and closure reports, and keep a traceable file of the whole action.
Who is responsible: the holder, not the foreign factory
RDC 551 was published on 30 August 2021 and took effect on 1 October 2021. It replaced RDC 23/2012 (Art. 19). Article 2 defines the detentor de registro as the company that holds the registration or notification of the product with ANVISA. That is the legal person in Brazil, not the manufacturer abroad.
The same article makes the holder and every other party from production to use (or disposal) jointly responsible for keeping the product’s quality, safety and effectiveness up to the end user. In practice ANVISA addresses the holder. If your distributor holds your registration, your distributor is the company ANVISA expects to plan, notify and run your recall in Brazil. That is one more reason I tell manufacturers to think hard before they let a commercial partner hold the registration.
What counts as a field action
Article 3 defines a field action (ação de campo) as an action by the manufacturer or registration holder that aims to reduce the risk of an adverse event related to a device that has already been marketed. It also defines:
Alert message: the holder’s communication to health professionals, patients, users and others about the risk of an adverse event.
Serious adverse event: death; permanent damage to a body structure; medical or surgical intervention to prevent permanent impairment; hospitalization or prolonged hospitalization; or fetal distress, fetal death or congenital anomaly.
Serious threat to public health: any occurrence that creates an imminent risk of death, serious injury or serious illness and calls for rapid corrective action.
Article 4 sets the trigger. The holder must start a field action as quickly as possible whenever there is sufficient evidence, or proof, that a device does not meet its applicable essential safety and effectiveness requirements. The holder is also the one who has to say whether marketing or importation of the affected lot or series must be suspended, unless the national health surveillance system decides it first (Art. 4, §2). Article 6 adds that the system can order a field action on its own, whatever the holder has or hasn’t done.
The clocks
All of the deadlines below are in calendar days, and they run from the decision to carry out the field action (Art. 8 and Art. 9, §1), not from the date the complaint arrived. That makes the date you document the decision important.
Situation
Deadline to notify ANVISA
Basis
The alert must run in mass-circulation media
3 calendar days (plus prior approval of the message within 5 calendar days)
Art. 9, I; Art. 8
Serious threat to public health
3 calendar days
Art. 9, II
Risk of a serious adverse event (not covered above)
10 calendar days
Art. 9, III
Any other field action
30 calendar days
Art. 9, IV
Notification goes in on ANVISA’s specific form (Art. 9, §2), and ANVISA can ask the holder to revise or complete it (Art. 9, §3). ANVISA’s instructions for the form say the notification form and the distribution map must be attached to the initial field-action petition. When the affected device has been implanted, the holder must also attach a follow-up plan for implanted patients covering, at a minimum, the patient list, how and how often patients will be contacted, what data will be collected and analyzed, what measures follow from the results, and how the plan’s effectiveness will be assessed.
Mass-media alerts need ANVISA’s approval first
If the alert has to go out through mass-circulation media, the holder must submit the message for ANVISA’s prior approval within 5 calendar days of the decision, under Art. 41-B of Law 9.782/1999 (Art. 8). ANVISA can approve it or point out corrections. Once approved, the holder must run it immediately. Prior approval does not replace the Art. 9 notification; both are required (Art. 8, §4).
What the alert message must say
Article 7 requires the holder to issue the alert as quickly as possible, in clear and objective language, with at least:
the problem;
the product: registration or notification number, product name, model and affected lot or serial numbers;
the risk the problem creates;
instructions for health professionals, patients, users and anyone else concerned.
The holder picks the most effective channel. For a hospital-only device that is usually direct letters to the risk managers of the hospitals on the distribution map. For a widely used product it may mean media, which brings in the Art. 8 approval step.
After the notification
Monitoring and closure reports go to ANVISA on the dates the holder declared in the action plan, on ANVISA’s model, with proof of completion (or a statement that the proof is on file) attached to the closure report (Art. 10). ANVISA can ask for reports on other dates (Art. 11).
Distributors must send the holder the distribution map and any other information needed, in good time (Art. 12). Put this obligation in your distribution agreements; a holder that can’t get a distribution map can’t meet a 3-day clock.
Patient and user assistance is mandatory when the device has been or is still being used, to bring the risk to an acceptable level and reduce harm already done (Art. 13).
Recalled product must be identified and segregated in a separate, secure area until its final destination is decided; if nothing is collected, the affected product still has to be identified and, where relevant, segregated (Art. 14). Destruction is the holder’s responsibility and must fully de-characterize the product (Art. 15).
Records: the holder keeps an up-to-date, traceable file of every field action, including proof of correspondence sent and received and proof of completion (Art. 16).
Written procedures for field actions are mandatory (Art. 5). ANVISA will ask for them, and an auditor will too.
Breaking these rules is a health infraction under Law 6.437/1977, without prejudice to civil, administrative and criminal liability, including under the Consumer Defense Code, Law 8.078/1990 (Art. 17).
A global recall usually becomes a Brazilian field action
The resolution doesn’t care where the problem was found. If your headquarters opens a recall or field safety corrective action in the US or Europe and the affected models or lots were shipped to Brazil, your Brazilian holder has to decide on a field action there and the clocks start from that decision. The coordination failure I see most often is a global quality team that issues its field safety notice and only tells the Brazilian holder days later. By then the 3- or 10-day window may already be closing.
How I set this up for a foreign manufacturer
Write the field-action SOP before launch, not after the first complaint (Art. 5). It names who in Brazil decides, who files, and how the decision date is recorded.
Wire the global quality system to the holder. The manufacturer’s complaint, CAPA and recall procedures should name the Brazilian holder as a party that is notified the same day a field action is considered for any lot shipped to Brazil.
Keep the distribution map current. Contract distributors to deliver it on demand (Art. 12), down to lot and serial number for implants.
Prepare the Portuguese alert template with the four Art. 7 elements, ready to fill in.
Plan for implants. If you sell implantable devices, draft the patient follow-up plan structure in advance; ANVISA’s form instructions ask for it with the initial notification.
That is what a registration holder is for. At bioaccess® we provide an independent ANVISA registration holder service for foreign manufacturers, so the company answering to ANVISA on a field action is not the same company that sells your product. Pricing is two-part, a one-time registration fee plus an annual holder fee, as set out on our market-access page.
FAQ
Does RDC 551 apply to devices under notification as well as registration?
Yes. Article 2 defines the holder as the company that holds the registration or the notification of the product with ANVISA, so lower-risk notified devices are covered too.
When does the 10-day clock start?
From the decision to carry out the field action (Art. 9, §1). Document that decision with a date.
Can the distributor run the recall?
Distributors must supply the distribution map and information on time (Art. 12), but notification and the action itself are the holder’s obligations. If your distributor is also your holder, it runs your recall.
What did RDC 551 replace?
RDC 23/2012 and RDC 501/2021 (Art. 19). RDC 551 took effect on 1 October 2021 (Art. 20).
Sources: ANVISA RDC 551, of 30 August 2021 (DOU), Arts. 1 to 20; ANVISA field-action page and the instructions for completing the field-action notification form.
General information, not legal or regulatory advice. Sources checked on 25 October 2026. bioaccess® is not affiliated with any company named on this page, and describes other companies only by what they publish themselves.
Signs you are behind
The registered primary completion date has passed and the study still shows recruiting.
Sites have been added mid-study.
Screen-failure rates are higher than the protocol assumed.
The U.S. Food and Drug Administration (FDA) accepts device data from outside the United States under 21 CFR 812.28 when the study follows good clinical practice (GCP), has independent ethics review and informed consent, and FDA can validate the data. The rule is the same whether the sites are in Central Asia, the Caucasus or Latin America.
How Latin America compares
Same FDA rule: 21 CFR 812.28.
Published clocks: our Panama hub publishes 3–5 week ethics approval and a 6–8 week average to first patient with bioaccess® coordination; our Brazil hub publishes 6–10 weeks for ANVISA plus ethics review.
Time zone: 0–2 hours from U.S. Eastern.
U.S. continuity: bioaccess® is headquartered in Miami; its sister organization Amavita Research Services runs a Miami device and early feasibility study site.
Trade-offs: Spanish or Portuguese documents and investigational import permits.
General information, not legal or regulatory advice. Sources checked on 25 October 2026. bioaccess® is not affiliated with any company named on this page, and describes other companies only by what they publish themselves.
What the registry shows
Magenta Medical: NCT07293923 lists sites in Georgia and Israel.
Endomatic: NCT06099106 lists a site in Tashkent, Uzbekistan.
ENTire Medical: NCT06438185 lists sites in Uzbekistan and Israel.
Sanoculis: studies such as NCT05638321 list a site in Armenia.
Precise Bio: NCT07325097 lists sites in Armenia and Israel.
We describe these studies only by their public registry entries and draw no conclusion about any company’s choices.
Standards and U.S. data acceptance
The U.S. Food and Drug Administration (FDA) accepts device data from outside the United States under 21 CFR 812.28 when the study follows good clinical practice (GCP), has independent ethics review and informed consent, and FDA can validate the data. The rule is the same whether the sites are in Central Asia, the Caucasus or Latin America.
How Latin America compares
Same FDA rule: 21 CFR 812.28.
Published clocks: our Panama hub publishes 3–5 week ethics approval and a 6–8 week average to first patient with bioaccess® coordination; our Brazil hub publishes 6–10 weeks for ANVISA plus ethics review.
Time zone: 0–2 hours from U.S. Eastern.
U.S. continuity: bioaccess® is headquartered in Miami; its sister organization Amavita Research Services runs a Miami device and early feasibility study site.
Trade-offs: Spanish or Portuguese documents and investigational import permits.
General information, not legal or regulatory advice. Sources checked on 25 October 2026. bioaccess® is not affiliated with any company named on this page, and describes other companies only by what they publish themselves.
U.S. and Israeli device companies are running first-in-human (FIH) studies in Uzbekistan and Kazakhstan. This page sums up what the public registry shows country by country.
Country snapshot (ClinicalTrials.gov)
Industry-sponsored studies with a site in each country and a start date in 2021 or later (ClinicalTrials.gov API v2, pulled 25 October 2026):
Kyrgyzstan, Tajikistan, Turkmenistan: no industry-sponsored studies listed on ClinicalTrials.gov in that window. That does not mean no trials run there; it means none are registered on that registry.
Who facilitates these studies
The registry rarely names a CRO. In Uzbekistan, the only CRO named as a collaborator on industry device studies we found is Clinical Accelerator, on four studies (e.g. NCT07811024, NCT05592392).
One FIH, two regions
At least one U.S. device sponsor has publicly announced a first-in-human study enrolling at centers in both Uzbekistan and Paraguay (sponsor press release, October 2025). Latin America and Central Asia are not either/or: a sponsor can enroll in both under one protocol.
Standards and U.S. data acceptance
The U.S. Food and Drug Administration (FDA) accepts device data from outside the United States under 21 CFR 812.28 when the study follows good clinical practice (GCP), has independent ethics review and informed consent, and FDA can validate the data. The rule is the same whether the sites are in Central Asia or Latin America.
How Latin America compares
Same FDA rule: 21 CFR 812.28.
Published clocks: our Panama hub publishes 3–5 week ethics approval and a 6–8 week average to first patient with bioaccess® coordination; our Brazil hub publishes 6–10 weeks for ANVISA plus ethics review.
Time zone: 0–2 hours from U.S. Eastern.
U.S. continuity: bioaccess® is headquartered in Miami; its sister organization Amavita Research Services runs a Miami device and early feasibility study site.
Trade-offs: Spanish or Portuguese documents and investigational import permits.
Which Central Asian countries host industry device trials?
On ClinicalTrials.gov, Uzbekistan and Kazakhstan do; Kyrgyzstan, Tajikistan and Turkmenistan had no industry-sponsored studies listed with a 2021-or-later start as of 25 October 2026.
Will the FDA accept FIH data from Central Asia or Latin America?
It can, under 21 CFR 812.28, if the study follows GCP and FDA can validate the data. The decision is case by case.
Can one FIH run in Central Asia and Latin America?
Yes. At least one U.S. device sponsor has announced an FIH study enrolling in both Uzbekistan and Paraguay.
A few weeks before the first case, a sponsor almost always asks me the same thing: our implanting physician from the US wants to proctor the first cases, and our field clinical engineer will be in the room. Do they need anything from the local authorities? The answer is yes for the physician in most of Latin America. For the engineer it depends on what he or she touches.
I am Julio Martinez-Clark, CEO of bioaccess®. This page sets out what the public rules say in Colombia, Brazil and Panama about foreign physicians taking part in procedures, how that interacts with 21 CFR Part 812, and how I plan the paperwork so the first case doesn’t slip. It sits next to our early feasibility studies page, the Panama FIH guide and the clinical trial insurance guide. This is operator guidance, not legal advice. Confirm the current requirements with the site and the local medical college before you book flights.
One-sentence answer
A foreign physician who performs or scrubs into a procedure in a Latin American trial needs a temporary authorization from the local medical regulator, requested by the host institution, with home-country licenses, a named local team that stays responsible for the patient, and in Colombia a liability policy and a declared purpose that is not promotional. A sponsor engineer who stays off the sterile field and never handles the device while it is in the patient is usually treated as technical support, not as practicing medicine.
Why this is a regulatory question, not a travel question
Medicine is a licensed profession in every country in the region. A business visa lets someone enter the country. It does not let them operate. When a foreign physician treats a study subject without the local authorization, the problem lands on the site, on the investigator who allowed it and on the data. An ethics committee or a monitor who finds an unlicensed operator in the procedure notes will ask questions you don’t want in an FDA submission.
Colombia: permiso transitorio
Colombia has the most detailed public framework I know of in the region.
Legal basis. Ley 1164 de 2007, Art. 18, parágrafo 3, grants foreign health personnel who come in scientific missions or to provide services of a humanitarian, social or research character a temporary permit for the length of the mission, which must not exceed six months. Extensions are only for exceptional, documented cases. Parágrafo 3 says the permit is issued by the Ministry of Health directly or through the professional colleges with delegated public functions, and Art. 10(c) lists issuing it among those colleges’ functions.
Procedure. Decreto 780 de 2016, Arts. 2.7.2.1.3.1 to 2.7.2.1.3.3 (which took over Arts. 21 to 23 of Decreto 4192 de 2010), set out the request. The Ministry’s Circular Externa 024 of 6 July 2018 explains how the colleges apply it. A denial by a college can be appealed to the Ministry.
The commercial exclusion. Circular 024 says no permit will be granted when the purpose, the activities or one of the objectives of the mission is the promotion, advertising, sponsorship or commercialization of services, procedures, medicines, devices or health technologies. A clinical investigation is research, but write the request so that the purpose is plainly the protocol, not training for a commercial launch.
Payment. The circular says paying the foreign professional’s fees or expenses does not by itself make the mission for-profit. If a Colombian institution pays the visiting physician, the request has to say so and explain why personnel licensed in Colombia were not used. No payment may come from the patients.
Host IPS. The mission must be supported by a health provider (IPS). The request names the IPS and the services used, with a letter from its legal representative accepting responsibility for the consequences for patients. The college checks those services are enabled in the REPS registry.
Insurance. Once the permit is granted, the responsible organization must take out a collective civil liability policy of no less than 250 monthly minimum wages, covering the mission plus 12 months, with an insurer supervised by the Superintendencia Financiera. The territorial health authority asks for it before the mission starts. This is separate from the study’s clinical trial insurance.
Brazil: autorização especial from the CRM
In Brazil the route runs through the regional medical council (CRM) under Resolução CFM nº 1.494/1998, which covers medical acts performed as didactic demonstrations by foreign physicians invited by universities, official bodies, associations and scientific institutions. Art. 1 asks the inviting institution to give the CRM:
the names of the invited medical team;
proof that they entered Brazil lawfully;
original documents from their home countries proving they are licensed;
a program, approved by the sponsoring institution, with the place of the procedures, proof of technical capacity, the local medical team and each member’s level of responsibility, patient selection criteria without discrimination, the immediate and late post-operative plan including complications, the patient’s informed consent and a favorable opinion from the institution’s medical ethics committee.
Art. 2 makes the institution’s technical director responsible for compliance. Art. 3 forbids charging any payment for the medical acts performed. The CFM’s service page asks for the request at least 30 days in advance, with a responsibility statement signed by the institution’s technical director. I plan for that 30-day window as a minimum, on top of the CEP and ANVISA approvals the trial already needs.
MINSA states publicly that medicine in Panama is a profession reserved for nationals. Ley 69 de 2013 lets MINSA and the Caja de Seguro Social hire foreign health professionals temporarily, but it is a public-sector hiring route with exams and a temporary registry. It is not designed for a visiting proctor.
For a visiting physician, Panama’s procedure guides list a MINSA procedure, handled by the Dirección General de Salud, that authorizes foreign physicians to take part in demonstrations and surgical procedures together with Panamanian physicians in public and private hospitals. The request is a formal letter from the hospital or medical association, with the invited physicians’ licenses and certificates of good standing. Read the word “together”: the Panamanian investigator stays in the case.
Other countries
Each country has its own route, usually through the medical college or the health ministry, and the requirements change. Don’t assume a rule from one country carries over to the next. Ask the site’s medical director early which authority grants the permit, who files it and how long it takes. If nobody at the site has done it before, that is a feasibility finding.
Where 21 CFR Part 812 fits
Who is an investigator. 21 CFR 812.3(i) defines the investigator as the person under whose immediate direction the device is used on a subject. A proctor who performs part of the procedure is doing investigator work. List the proctor on the site’s delegation log with the tasks delegated, and make sure the local principal investigator stays responsible.
Qualified investigators. 812.43(a) requires the sponsor to select investigators qualified by training and experience. The local authorization is part of the evidence that the person was qualified to act in that country.
Data you want FDA to accept. If the study will support an IDE or a marketing submission, 812.28(b) asks for the names and qualifications of the investigators. A case run by someone without local authorization is a weak point in that file.
No promotion. 812.7(a) prohibits promoting an investigational device. It lines up with Colombia’s commercial exclusion. Keep proctoring framed as protocol support.
Field clinical engineers
Engineers set up consoles, check software versions, confirm device sizes and answer technical questions. That is normal in early feasibility work. Here is the line I hold:
Off the sterile field, no hands on the patient and no hands on the device while it is in the patient.
Name the role in the protocol or the monitoring plan, and the tasks on the delegation log.
Hospital access, confidentiality and any badge or induction the hospital requires are agreed with the site before the visit.
If the engineer has to do more than that, treat it as a clinical role and run it through the authorization route above, or train a local team member to do it.
Mistakes I see
Booking the first case before the permit is granted, then pushing the date when the college asks for an apostilled document.
A request that reads like a product launch or a training tour, which in Colombia is a reason to refuse it.
No local physician named as responsible for post-operative care and complications.
Assuming the clinical trial insurance policy covers the foreign physician. In Colombia the mission needs its own civil liability policy.
No delegation-log entry for the proctor, which shows up at the first monitoring visit.
How bioaccess® runs this
bioaccess® plans the proctor and engineer plan during site selection, works with the site’s medical director to prepare the authorization request, collects and apostilles the licenses and certificates, and lines up the permit date with ethics and regulatory approvals and device import. Study scope and pricing are set at proposal. Start on our early feasibility studies page, see market access for the country pages, or book a call.
Operator checklist
At feasibility, ask the site which authority grants the visiting-physician permit and how long it takes.
Collect home-country licenses, certificates of good standing and diplomas, apostilled, at least 6 weeks before the first case.
Write the request around the protocol: purpose, dates, procedures, patients, local team.
Colombia: name the IPS, get its legal representative’s letter, declare any payment and buy the 250-minimum-wage liability policy for the mission plus 12 months.
Brazil: file with the CRM at least 30 days ahead with the CFM 1.494/1998 program and the ethics committee opinion.
Panama: the hospital files the MINSA request; the Panamanian investigator stays in the case.
Put the proctor and the engineer on the delegation log with defined tasks.
Keep the permit in the investigator site file, ready for monitoring and for an FDA 812.28 package.
General information, not legal or regulatory advice. QLINICO Consulting is a separate, independent company. bioaccess® is not affiliated with, endorsed by, or sponsored by QLINICO Consulting, and this page does not describe, evaluate or compare QLINICO Consulting’s services. The checklist below applies equally to every provider, including bioaccess®. For information about QLINICO Consulting, contact that company directly. Regulatory requirements and timelines change; confirm them for your protocol with MINSA and your ethics committee. Last reviewed 21 October 2026.
Sponsors planning an early clinical study in Panama will come across several providers, including bioaccess® and QLINICO Consulting. This page does not evaluate any of them; it sets out the questions we suggest asking any Panama CRO, including us, and explains where bioaccess® fits. Panama is a strong choice for first-in-human device work, and the CRO you pick shapes how fast and how cleanly that study runs.
Why sponsors choose Panama for first-in-human studies
In April 2026 Panama published Decreto Ejecutivo No. 21, implementing Ley 84 of 2019. Under Article 91, for clinical trials MINSA and a CNBI-accredited Type II bioethics committee (CBI) evaluate the protocol in parallel, and studies are registered on MINSA’s RESEGIS platform before they start. When the Spanish file is complete and the right committee is selected, in our experience startup has typically taken roughly 30 to 45 days; timelines vary by study and committee, so confirm them per protocol. More detail: Panama and El Salvador parallel review.
What to check when choosing a Panama first-in-human CRO
Ask every bidder the same questions and get the answers in writing. These are the questions we would expect a sponsor to put to bioaccess® as well.
First-in-human track record. Which first-in-human or early feasibility device studies has the team run, in which device classes, and can references confirm them?
Regulatory and ethics pathway. How will the file reach a CNBI-accredited Type II CBI, how will RESEGIS registration be handled, and who owns import permits for the investigational device?
Independent medical and safety oversight. Who is the named medical monitor, how are adverse events escalated, and how is medical-monitor safety review kept separate from the investigational site’s clinical team, as ISO 14155:2020 and the protocol require?
Insurance and sponsor representation. How are clinical trial insurance and local legal representation for a foreign sponsor arranged?
FDA-ready data. Will the study meet 21 CFR 812.28 and ISO 14155:2020, with an inspection-ready trial master file and source documents an English-speaking inspector can follow? See Panama and El Salvador FIH data for FDA.
Continuity planning. Who are the named project manager, clinical monitor and data manager for your study, and what is the written continuity plan if a team member, site or country is delayed?
Scope clarity. Ask each bidder to map its price to a line-item scope (regulatory, ethics, monitoring, data management, medical monitoring, insurance, importation, sponsor representation) so bids can be compared on the same basis.
Where bioaccess® fits
First-in-human focus. bioaccess® is a first-in-human CRO focused on the Americas, running first-in-human and early feasibility trials for medtech, biotech, biopharma and radiopharma, with neurotechnology among its therapeutic areas.
FDA strategy from Miami. We plan each study around the sponsor’s FDA endgame, then run it where it moves fastest.
Panama pathway. We work with MINSA and with Panama’s ethics committee pathway under Decreto Ejecutivo No. 21 of 2026.
Latin American network. Since 2010 we have supported more than 50 client companies, work with more than 100 sites, and cover 19 Latin American and Caribbean countries for device registration and market access, so a Panama study can have a second country ready if needed. See Latin America rapid-startup archetypes.
Frequently asked questions
Is bioaccess® connected to QLINICO Consulting or any other Panama CRO?
No. bioaccess® is an independent contract research organization with no affiliation with QLINICO Consulting or any other Panama provider. This page does not evaluate other providers; sponsors should obtain information about them directly.
What should a sponsor check before choosing a CRO in Panama?
Ask every bidder for documented first-in-human experience in your device class, how it will route the file to a CNBI-accredited Type II ethics committee and register it in RESEGIS, who provides medical monitoring and safety oversight, how insurance and local sponsor representation are handled, how the trial master file is kept inspection-ready for FDA under 21 CFR 812.28, and what the backup plan is if a single site or country slows down.
How long does clinical trial startup take in Panama?
Under Decreto Ejecutivo No. 21 of 2026, Article 91, MINSA and an accredited Type II ethics committee review high-risk and clinical-trial protocols in parallel. When the Spanish file is complete and the right committee is selected, in our experience startup has typically taken roughly 30 to 45 days; timelines vary by study and committee, so confirm them per protocol.
Can first-in-human data from Panama support an FDA submission?
Yes, when the study is designed for 21 CFR 812.28 from day one: conduct in accordance with good clinical practice (FDA recognises ISO 14155:2020 as a consensus standard, and conformance supports but does not by itself establish GCP compliance), independent ethics review, documented informed consent, monitoring, and a trial file FDA can inspect.
When a manufacturer brings me an FDA-cleared or CE-marked powered device for Brazil, the timeline conversation usually starts with ANVISA. It should start one step earlier. For electromedical equipment, ANVISA won’t grant, change or revalidate the registration without a Brazilian conformity certificate, and a device with a radio inside needs a separate ANATEL homologation before it can be sold. Neither is replaced by your CB report, your 510(k) or your CE certificate.
I am Julio Martinez-Clark, CEO of bioaccess®. This page explains the two certifications that sit in front of many ANVISA device files: compulsory conformity certification under RDC 549/2021, usually called “INMETRO certification”, and ANATEL homologation under Resolução 715/2019. It sits alongside our Brazil ANVISA registration page, the Brazil registration holder guide and the LATAM market-access hub. This is operator guidance, not legal advice.
One-sentence answer
Under ANVISA RDC 549 of 30 August 2021, medical, dental, laboratory, physiotherapy and aesthetic equipment must carry a conformity certificate issued within the Brazilian conformity assessment system (SBAC) by an Inmetro-accredited certification body established in Brazil, against the standards listed in ANVISA IN 283/2024, and the supplier must present it to grant, change or revalidate the ANVISA registration or notification. Any telecom function needs ANATEL homologation, which Resolução 715/2019 Art. 55 makes a mandatory prerequisite for use and sale in Brazil.
Which devices need the conformity certificate
RDC 549/2021 (in force since 1 October 2021) covers “equipment under health surveillance”, including parts and accessories. Article 2 §2 defines two groups:
equipment with a medical, dental, laboratory or physiotherapy purpose, used directly or indirectly for diagnosis, treatment, rehabilitation or monitoring in humans;
equipment for beautification and aesthetics.
The test is whether the product is equipment within the field of application of a listed standard, not its risk class. Article 3 applies to both registration (registro) and notification files. So a Class II notified device can need the certificate just as a Class III registered one does. Article 2 §3 also says the certificate isn’t the only proof of safety and efficacy, and ANVISA can still ask for more studies.
Which standards apply: IN 283/2024
RDC 549 points to a list of technical standards set by ANVISA instruction. The current list is Instrução Normativa 283 of 7 March 2024, in force from 1 April 2024, which revoked IN 116/2021. Annex I lists the ABNT NBR IEC 60601 family: the general standard 60601-1, collaterals such as 60601-1-2 (electromagnetic disturbances), 60601-1-6 (usability) and 60601-1-8 (alarm systems), and the particular standards for specific equipment types.
Annex II sets a transition worth putting on your calendar. ABNT NBR IEC 60601-1:2010 with Amendment 1:2016 is the version currently enforced. The version with Amendment 2:2022 becomes compulsory on 31 December 2027, and 60601-1-2 with Amendment 1:2022 follows the same date. If your test reports predate Amendment 2, ask your certification body now whether a renewal or change filing after that date will need new testing.
Two other IN 283 provisions help in practice. Article 2: when no accredited Brazilian lab can run part of a standard, the certification body justifies the gap and lists the exclusions on the certificate. Article 3: if ANVISA asks you to add a standard that you believe doesn’t apply, you answer with a technical justification, which you may have a certification body issue.
Who issues the certificate
Inmetro’s FAQ (updated 7 April 2026) states that the certification is performed by a product certification body (OCP) established in Brazil and accredited by Inmetro, under Portaria Inmetro 384 of 18 December 2020 as amended by Portaria 254 of 9 June 2021. That portaria sets the conformity assessment requirements and the identification seal. Two details in the portaria are worth knowing:
Article 2 says Inmetro doesn’t regulate these products technically. ANVISA sets the requirements; Inmetro accredits the bodies that check them.
Article 6-A lets the certificate expire early if the certification body or ANVISA finds the manufacturer changed the design in a way that critically affects safety.
The OCP runs the evaluation its certification scheme sets out. Pick it early and agree with it which of your existing reports it can accept.
What the certificate does in the ANVISA file
Grant, change and revalidation (RDC 549 Art. 3). The supplier presents a copy of the certificate. Changes that count are those that affect the standards used in the certification, and the certification body that issued the certificate assesses that impact.
A shortcut for imports (Art. 3 §1). An importer filing a certified imported device is exempt from presenting the certificate of free sale or origin-country registration. That is useful for devices whose home approval is still pending, a problem I covered in the certificate of free sale trap.
Summary rejection (RDC 751/2022 Art. 10 §4). Under ANVISA’s device registration rule, a petition missing a required conformity certificate isn’t sent a deficiency letter; it can be refused outright.
Suspension (RDC 751/2022 Art. 39). ANVISA can suspend manufacture, import, distribution, sale and use when a compulsory conformity certificate is missing.
When certification isn’t possible
RDC 549 Article 4 covers equipment that can’t be certified in the SBAC at the time of filing. The applicant presents a declaration from an Inmetro-accredited certification body explaining why. Once capacity exists, the holder has 180 days to present the certificate, and missing that window starts suspension and cancellation. Where the problem is partial and temporary, the file instead carries a consolidated report from an OCP, in Portuguese and showing conformity on every item checked. For equipment tested abroad, the OCP can build that report on test reports from labs accredited by ILAC signatories, as long as they cover at least the items that can be tested in Brazil.
Keeping it valid
Article 7 makes the certificate a condition for keeping the registration. If it is canceled or expires during the registration’s life, you have 90 days to present a new one; past that, suspension and cancellation procedures start. The 90 days don’t apply if the certificate was pulled because the product failed the standards. Put certificate expiry and surveillance audits in the same tracker as the ANVISA revalidation.
ANATEL: the radio is a separate product
If the device has Bluetooth, Wi-Fi, cellular or another radio, a second regime applies. ANATEL’s Resolução 715 of 23 October 2019 defines a telecommunications product as equipment, apparatus, device or element that is necessary or sufficient to carry out telecommunications, including accessories and peripherals (Art. 4, XVI). Article 55 makes homologation a mandatory prerequisite for using and selling such products in Brazil. Since Resolução 780 of 1 August 2025, Article 55 §1 also lets ANATEL require homologation before import in cases it defines by operational procedure.
The certificate comes from a designated certification body that the applicant chooses (Art. 40), and the applicant has to show it can meet Brazilian consumer guarantees, including product information, warranty and technical assistance (Art. 21). ANATEL homologation and the RDC 549 certificate are separate procedures under separate agencies. Plan both, and decide early which Brazilian company applies for each one.
How bioaccess® handles it
bioaccess® acts as your Brazil Registration Holder under contract with you, working with our local partner in Brazil, and files the ANVISA dossier. Before filing, we map which IN 283 standards apply, collect your existing test reports, coordinate the Brazilian OCP and any ANATEL designated certification body, and line up the certificates with the registration timeline. As the Brazil page states, INMETRO and ANATEL work is not included in the registration and holder fees and is quoted separately, as is Brazil GMP. Brazil pricing is two-part: a one-time registration fee plus an annual holder fee. If you are planning a clinical study rather than a launch, start with clinical trials in Brazil.
Operator checklist
Check whether your device is equipment within the field of a standard in IN 283/2024 Annex I, whatever its risk class.
Choose an Inmetro-accredited OCP established in Brazil and agree which existing reports it accepts.
Check your 60601-1 and 60601-1-2 reports against the 31 December 2027 Annex II date.
If certification isn’t possible, get the Article 4 OCP declaration and track the 180-day clock.
Identify every radio function and plan ANATEL homologation before import and sale.
Track certificate expiry with the 90-day replacement window in Article 7.
Have the certification body assess design changes before you file a registration change.